Product detail:
1.Special functions for the disabled: It applies horizontal installation of buttons in the elevator car. It also prints braille in the buttons. It is convenient for the disabled to enter into / exit from the elevator.
2.It prolongs time-delay door-closing. After the elevator fully opens the door, it keeps door-opening. After time-delay, it automatically closes the door. It is convenient for the medical staff to safely enter into / exit from the elevator.
Hospital elevator specification:
Load(kg) | Persons | Speed(m/s) | Door open type | Entrance | Car net size | Shaft inside dimension | Machine room size | |||
(JJ*HH)mm | (AA*BB)mm | (AH*BH)mm | PP | OH | (W*D)mm | |||||
Single | Opposite(optional) | |||||||||
1600 | 21 | 0.63/1.0 | 2-panel side opening | 1200*2100 | 1400*2400 | 2400*3000 | 2400*3060 | 1500 | 4500 | 3200*4200*2800 |
1.5/1.75 | 1800 | 4800 | ||||||||
0.63/1.0 | Center-opening | 1000*2100 | 2500*2900 | 2500*2930 | 1500 | 4500 | ||||
1.5/1.75 | 1800 | 4800 | ||||||||
2000 | 26 | 0.63/1.0 | 2-panel side opening | 1300*2100 | 1500*2700 | 2500*3300 | 2500*3360 | 1500 | 4500 | 3300*4300*2800 |
1900 | ||||||||||
Center-opening | 1100*2100 | 2600*3200 | 2600*3230 | 1500 | ||||||
1900 |
MRL hospital elevator specification:
Load(kg) | Persons | Speed(m/s) | Entrance | Car net size | Shaft inside dimension | ||
(JJ*HH)mm | (AA*BB)mm | (AH*BH)mm | PP | OH | |||
630 | 8 | 1.0 | 800*2100 | 1300*1250 | 2250*1700 | 1600 | 4000 |
1.5/1.75 | 1800 | 4300 | |||||
800 | 10 | 1.0 | 800*2100 | 1400*1400 | 2400*1900 | 1600 | 4200 |
1.5/1.75 | 1800 | 4500 | |||||
1000 | 13 | 1.0 | 900*2100 | 1500*1600 | 2500*2100 | 1600 | 4200 |
1.5/1.75 | 1800 | 4500 | |||||
1600 | 21 | 0.63/1.0 | 1000*2100 | 1900*1850 | 3000*2400 | 1600 | 4600 |
2.0/2.5 |
Function:
Standard function: | ||
Travel function | 1 | VVVF drive |
2 | VVVF door operator | |
3 | Independent running | |
4 | Automatic pass without stop | |
5 | Automatically adjust door opening time | |
6 | Reopen with hall call | |
7 | Express door closing | |
8 | Car stops and door open | |
9 | Car arrival gong | |
10 | Command register cancel | |
Safety function | 11 | Light curtain protection |
12 | Designated stop | |
13 | Overload holding stop | |
14 | Anti-stall timer protection | |
15 | Start protection control | |
16 | Inspection operation | |
17 | Fault self-diagnosis | |
18 | Repeated door closing | |
19 | Up/down over-run and final limit protection | |
20 | Down over-speed protection device | |
21 | Up over-speed protection device | |
Human-machine Interface | 22 | Micro-touch button for car call and hall call |
23 | Floor and direction indicator inside car | |
24 | Floor and direction indicator | |
Emergency function | 25 | Emergency lighting |
26 | Inching running | |
27 | Five way intercom | |
28 | bell | |
29 | Fire emergency return | |
Energy-saving function | 30 | Car fans/lighting automatic shut-off |
31 | Remote shut-off | |
Optional Function | ||
Emergency function | 1 | Leveling when power off |
Travel function | 2 | Anti-nuisance |
3 | Open the door in advance | |
4 | Direct parking | |
5 | Group control function | |
6 | Duplex control | |
7 | On-duty peak service | |
8 | Off-duty peak service | |
9 | Door open time extending | |
Human-machine Interface | 10 | Voice announcer |
11 | Car assistant operation box | |
12 | Operation box for the handicapped | |
13 | Intelligent calling service | |
14 | IC card control function | |
Monitor function | 15 | Remote monitor |
16 | Remote control | |
17 | Car camera |
Note:The above data is only for your reference. If you have any special request ,pls do not hesitate to contact with us anytime .